???item.export.label??? ???item.export.type.endnote??? ???item.export.type.bibtex???

Please use this identifier to cite or link to this item: https://bdtd.ucb.br:8443/jspui/handle/tede/2069
???metadata.dc.type???: Dissertação
Title: Ponto de inflexão do duplo produto como método alternativo para determinação do limiar ventilatório e de lactato e associação com indicadores de desempenho
???metadata.dc.creator???: Silva, Caio Victor de Sousa 
???metadata.dc.contributor.advisor1???: Simões, Herbert Gustavo
???metadata.dc.description.resumo???: A validade da resposta do duplo produto (DP) para estimar o limiar anaeróbio (LAn), um método alternativo e menos oneroso, ainda não foi testado em indivíduos com diabetes tipo 2 (DM2). Portanto, o objetivo deste estudo é verificar se é possível identificar o LAn pelo ponto de inflexão do duplo produto (DPBP) em indivíduos DM2. Nove sujeitos com DM2 (DM2 = 9) e dez não diabéticos (ND = 10) foram submetidos a um teste incremental em cicloergômetro. Frequência cardíaca (FC), pressão arterial (PA) e gases expirados foram mensurados ao final de cada estágio. O limiar ventilatório (LV), limiar de lactato (LL) e o DPBP foram considerados a intensidade do exercício abaixo a um aumento desproporcional da ventilação, [LAC] e DP, respectivamente, são observados em relação ao aumento linear da carga de trabalho. Não foram identificadas diferenças entre a carga de trabalho, FC, e consumo de oxigênio (VO2) correspondente ao LAn identificado pelo LV, LL e DPBP. Além disso, para o grupo DM2 foi identificado um alto e significante nível de confiabilidade entre DPBP e LV para carga de trabalho (ICC = 0,84), FC (ICC = 0,71) e VO2 (ICC = 0,83) e entre o DPBP e LL para carga de trabalho (ICC = 0,79) e FC (ICC = 0,82). Confiabilidade semelhante foi identificado para o grupo ND entre DPBP e LV para carga de trabalho (ICC = 0,92), FC (ICC = 0,88) e VO2 (ICC = 0,84) e entre o DPBP e LL para carga de trabalho (ICC = 0,70). Conclui-se que o DPBP permitiu a predição do LAn, devido ao alto nível de confiabilidade com os métodos tradicionais, LV e LL.
Abstract: The validity of the double product (DP) response to estimate the anaerobic threshold (AT), an alternative and less costly method has not been tested in patients with type 2 diabetes (T2D). Therefore, the objective of this study is test the reliability of AT identification by the double product breakpoint (DPBP) in T2D. Nine subjects with type 2 diabetes (T2D = 9) and ten non-diabetic (ND = 10) underwent an incremental test on a cycle ergometer. Heart rate (HR), blood pressure (BP) and exhaled gases were measured at the end of each stage. The ventilatory threshold (VT), lactate threshold (LT) and DPBP were considered an exercise intensity below which a disproportional increase of ventilation, [LAC] and DP, respectively, was observed in relation to linear increase in workload. No differences were identified between the workload, HR, and oxygen consumption (VO2) corresponding to the AT identified by VT, LT and DPBP. Further, for the T2D group was identified a high and significant level of reliability between DPBP and VT for workload (ICC = 0.84), FC (ICC = 0.71) and VO2 (ICC = 0.83) and between DPBP and LT for workload (ICC = 0.79) and FC (ICC = 0.82). Similar reliability was identified for the ND group between DPBP and VT for workload (ICC = 0.92), HR (ICC = 0.88) and VO2 (ICC = 0.84) and between DPBP and LT for workload (ICC = 0.70). It concludes that the DPBP is reliable to estimate the AT and it is highly associated with VT and LT in T2D and ND individuals.
Keywords: Limiar anaeróbio
Pressão sistólica
Frequência cardíaca
Doenças metabólicas
Teste de esforço
???metadata.dc.subject.cnpq???: CIENCIAS DA SAUDE::EDUCACAO FISICA
Language: por
???metadata.dc.publisher.country???: Brasil
Publisher: Universidade Católica de Brasília
???metadata.dc.publisher.initials???: UCB
???metadata.dc.publisher.department???: Escola de Saúde e Medicina
???metadata.dc.publisher.program???: Programa Strictu Sensu em Educação Física
Citation: SILVA, Caio Victor de Sousa. Ponto de inflexão do duplo produto como método alternativo para determinação do limiar ventilatório e de lactato e associação com indicadores de desempenho. 2016. 89 f. Dissertação (Programa Strictu Sensu em Educação Física) - Universidade Católica de Brasília, Brasília, 2016.
???metadata.dc.rights???: Acesso Aberto
URI: https://bdtd.ucb.br:8443/jspui/handle/tede/2069
Issue Date: 29-Feb-2016
Appears in Collections:Programa de Pós-Graduação em Educação Física

Files in This Item:
File Description SizeFormat 
CaioVictordeSousaSilvaDissertacao2016.pdfDissertação5.45 MBAdobe PDFThumbnail

Download/Open Preview


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.